The usual reasons a commercial fridge or freezer stops cooling โ and what to check before you lose stock.

A commercial fridge that's stopped cooling is a race against the clock โ every hour warm is stock at risk. Before you write off a load of food, here are the seven most common causes, and which ones you can check yourself.
The condenser coil sheds heat. Caked in dust and kitchen grease, it can't โ so the fridge runs constantly and still won't reach temperature. This is the single most common cause, and a clean often fixes it.
Perished or torn gaskets let warm air leak in. If the seal doesn't grip a sheet of paper shut in the door, it needs replacing.
A failed defrost or airflow problem ices over the internal coil and chokes cooling. Switching off to defrost may give a temporary fix, but the underlying fault needs diagnosing.
Low refrigerant means weak cooling and a compressor running non-stop. Leaks must be found and fixed by an F-Gas certified engineer โ never just topped up.
A dead evaporator/condenser fan, a faulty thermostat, or a failing compressor will all stop a fridge cooling properly โ these are engineer jobs.
Check the condenser isn't choked, the door seals grip, and nothing's blocking the internal vents. If it's still warm, don't gamble with stock โ arrange a fridge repair callout. Most Pembrokeshire breakdowns we attend the same day. Regular servicing catches most of these before they cost you a fridge full of food.
Yes โ keep it shut to hold temperature as long as possible and move the most at-risk stock to a working unit while you arrange a repair.
No โ handling refrigerant requires F-Gas certification by law, and a leak that's only topped up will simply fail again. It needs finding and fixing.